Facilities
Type of Facility
Organization of Facility
- (-) Remove LUT filter LUT (5)
- (-) Remove KTH filter KTH (3)
- IRSN (19) Apply IRSN filter
- KIT (8) Apply KIT filter
- CEA (7) Apply CEA filter
- European Commission (6) Apply European Commission filter
- MTA-EK (5) Apply MTA-EK filter
- Ciemat (3) Apply Ciemat filter
- Fortum (1) Apply Fortum filter
- FZ-Jülich (1) Apply FZ-Jülich filter
- ICN-Pitesti (1) Apply ICN-Pitesti filter
- Paul Scherrer Institut (1) Apply Paul Scherrer Institut filter
PACTEL is a volumetrically scaled (1: 305) facility including a pressurizer, high and low pressure emergency core cooling systems, and accumulators. The reactor vessel is simulated with a U-tube construction including separate downcomer and core sections.
To study the behavior of the PCCS configuration planned to be used in the ABWR II concept and to gain experimental data for the validation work of MELCOR severe accident code, a scaled down PCCS model was designed and constructed at Lappeenranta University of Technology in Finland in 2012–2013.
The PWR PACTEL facility consists of a reactor pressure vessel model, two loops with vertical steam generators, a pressurizer, and emergency core cooling systems. The new loops and steam generators of EPR style construction enable the PWR and EPR related experimental research.
The SIMECO (SImulation of MElt COolability) test facility consists of a slice type vessel, which includes a semi-circular section and a vertical section, representing the lower head of the reactor vessel. The size of the facility is scaled to be 1/8 of prototypic PWR type reactors.