Description:

In severe accidents with primary-to-secondary leakages, the retention of fission products in horizontal steam generators is poorly understood. The understanding of fission product deposition in realistic steam generator conditions is needed in realistic release estimates in PSA studies, and to design efficient accident management procedures. This is considered very important because steam generator tube rupture sequences are included in the risk dominant sequences.



Tube dimensions of the HORIZON model steam generator and Loviisa VVER-440 steam generators are approximately same. Thus it can be assumed that experiments give realistic results.



In addition to the steam generator section itself, the HORIZON facility includes a lot of equipment needed for steam and aerosol generation, and for measuring the thermal-hydraulic parameters as well as the aerosols concentrations.



The inlet and outlet chamber aerosol mass concentration is monitored with Tapered Element Oscillating Microbalance (TEOM) on-line mass monitor and the particle size distribution is measured on-line with the Electrical Low Pressure Impactor (ELPI). Aerosol sampling system includes heated sampling lines, two diluters (first diluter in system pressure is computer controlled and uses heated dilution air), pressure reducer and sampling valves. It is possible to change sampling point between inlet and outlet chambers.

Facility is dismanteled.

Organization
KTH
Type of Facility
Corium
Experiments available
1
Description:

Reactor cavity flooding is a cornerstone of severe accident management strategy in Swedish type BWRs. In a hypothetical severe accident with core melting and reactor vessel melt-through, it is assumed that the melt ejected into a deep water pool will fragment, quench and form a porous debris bed coolable by natural circulation. If natural circulation cannot remove decay heat produced by the debris, then dryout, reheating and remelting of the debris bed is expected to occur. Attack of molten core materials on the reactor containment base-mat presents a threat to containment integrity. Amount of the heat which can be removed by natural circulation from the debris bed is contingent, among other factors, upon the properties of the bed as porous media. Debris agglomeration and especially formation of “cake” regions can significantly increase hydraulic resistance for the coolant flow and thus negatively affect coolability of the debris bed. If melt is not completely solidified prior to settlement on top of the debris bed, then agglomeration of the debris and even “cake” formation is quite possible.

Organization
KTH
Type of Facility
Corium
Experiments available
1
Description:

The SIMECO (SImulation of MElt COolability) test facility consists of a slice type vessel, which includes a semi-circular section and a vertical section, representing the lower head of the reactor vessel. The size of the facility is scaled to be 1/8 of prototypic PWR type reactors. Fig.1 shows a schematic of the facility and Fig.2 shows the main dimensions of the vessel test section. The diameter and height of the test section are 620 mm and 530 mm, respectively. The width of the test section is 90 mm. The front and back faces of the facility are insulated in order to decrease heat losses. The vessel’s wall, represented by a 23-mm thick brass plate, is cooled by a regulated water loop. On the top of the vessel a heat exchanger with regulated water loops is employed to measure the upward heat transfer. The sideways and downward heat fluxes are measured by employing array of thermocouples at several different angular positions. Practically isothermal boundary conditions are provided at pool boundaries. A cable-type heater 3 mm in diameter and 4 m in length is submerged in the pool and provides internal heating. A heat exchanger mounted on the exit of cooling water, is employed to maintain the cooling capacity of the water. The isothermal bath is designed to provide constant temperature. A circulation pump was mounted in order to establish necessary flow rate. One digital and one analog flowmeter were mounted to measure water flow through the wall of the slice, while one analog flowmeter is used to measure the flow in the upper heat exchanger.

Facility is in operation.

Organization
KTH
Type of Facility
Corium
Experiments available
1
Description:

FOREVER program at KTH was concerned with the vessel integrity under the molten corium attack in the reactor lower plenum during a severe accident. Total 9 tests were performed in the FOREVER program, to simulate the behavior of the lower head of a reactor pressure vessel (RPV) under different conditions: French steel/American steel, with/without penetrations, with/without gap cooling.



The facility employs a 1/10th scaled lower head (hemispherical in shape and made of SA533B, American reactor steel) of 400 mm outer diameter and 15 mm wall thickness. A cylindrical shell of 15Mo3 German steel, of 400 mm height and thickness of 15 mm, was welded to hemispherical lower head to make a complete vessel.

Facility is in operation.