Skip to main content
Storage of Thermal REactor Safety Analysis data
Displaying 49 - 61 of 61 results
Organization
Type of Facility
Corium
Experiments available
0
Description:

The tests conducted in the PRELUDE facility help to validate key technical options for PEARL:

  • Induction heating to obtain heating sequences between 100-300 W/kg with homogeneous distribution in the different particle beds (slightly oxidised steel balls with 1, 2, 4 and 8 mm diameters), as well as to reach a temperature of 1,000°C at the hottest spot in the debris bed.
  • Material of the test section ensuring the thermomechanical resistance of the tube containing the particles bed,
  • Instrumentation to record the fi rst thermohydraulic measurements at atmospheric pressure when refl ooding the particle bed (about 25 kg) heated to of 400, 700 and 1,000°C.

This modular facility will remain operational to support the larger-scale PEARL facility (debris bed of about 500 kg) for complementary separate effects tests.

Facility is not operating, now called PEARL.

Organization
KIT
Type of Facility
Corium
Experiments available
0
Description:

The ECO facility, housed inside the large FAUNA steel vessel, was designed for investigating energy conversion ratios up to 20 %, related to 10 kg of melt. In principle, it consists of a piston/ cylinder system having 4 m in the total height. The melt generator providing the melt (≈ 2600 K) is part of the cylinder. The water pool has 0.6 m in diameter, and up to 1.3 m in depth. The steam explosion is triggered by two explosion capsules located in the centre and at the edge of the bottom of the pool. The test vessel (”piston”), under the pressure forces developing due to the steam explosion, moves downwards against the resistance of the underlying crushing material.

Organization
KIT
Type of Facility
Corium
Experiments available
0
Description:

The facility models the reactor pressure vessel (RPV), part of the reactor cooling system (RCS), the cavity, and the pump and steam generator rooms. The length scale is 1:18, compared to a large European reactor.

The pressure vessel consists of a steel pipe with a model of the RPV (outer diameter 298.5 mm) at its lower end. It has a total volume of 0.0879 m³, that models the volume of the pressure vessel and the volume of part of the RCS. The lower head of the RPV can hold 3.4 10-3 m³ of liquid, which corresponds to 20 m³ or 160 t of corium.



The cavity, a Plexiglas cylinder with an inner diameter of 342 mm, is attached to the vessel support structure. Generally, the flow path out of the reactor pit is through the annular gap between reactor vessel and cavity wall and along the main cooling lines into the pump and steam generator compartments. There is the option of a flow path through holes straight up into the containment, that is modeled by an extra cylindrical compartment.



The compartments, eight boxes which model in volume the steam generator and pump rooms (0.3 m³ and 0.131 m³ each respectively), are connected to the nozzles, and are placed on the vessel support structure around the RPV. They are covered by filters on their tops for the extraction of fog and drops. Two boxes have one Plexiglas wall each, to permit optical access for flow visualization.



The following failure modes of the lower head were studied: central holes and three types of lateral breaches: lateral holes, a horizontal slot, and complete ripping and tilting of the lower head. The horizontal slot models a partial rip in the lower head, as it might occur with a sidepeaked heat flux distribution. The flow cross section is equivalent to a 25 mm hole. The fluids employed were water or a bismuth alloy (similar to Wood’s metal) instead of corium, and nitrogen or helium instead of steam. Most experiments were performed for the combination water/nitrogen, with 3.410-3 m3 of water. With central holes four hole sizes, 15, 25, 50 and 100 mm diameter (scaled 0.27 m – 1.80 m), were investigated, each at three initial pressures, 0.35, 0.6 and 1.1 MPa. Nitrogen/metal tests were performed with the 25 and the 50-mm-hole at 0.6 and 1.1 MPa with 3.310-3 m3 of metal. Some tests (25 and 50 mm hole size) were performed with 1.810-3 m3 of water and were repeated several times. The reproducibility was very good.

Facility is in operation.

Organization
CEA
Type of Facility
Corium
Experiments available
9
Description:

In the hypothetical case of a nuclear reactor severe accident, the reactor core could melt and form a mixture, called corium, of highly refractory oxides (UO2, ZrO2) and metallic or oxidized steel, that could eventually flow out of the vessel and mix with the basemat decomposition products (generally oxides such as SiO2, Al2O3, CaO, Fe2O3, …).
The VULCANO experimental facility is operated to perform experiments with prototypic corium (corium of realistic chemical composition including depleted UO2). This is coupled with the use of specific high-temperature instrumentation requiring in situ cross calibration.
Due to the complex behavior of corium in the solidification range, an interdisciplinary approach has been used combining thermodynamics of multicomponent mixtures, rheological models of silicic semisolid materials, heat transfer at high temperatures, free-surface flow of a fluid with temperature-dependant properties.
Twelve high-temperature spreading tests have been performed and analyzed. The main experimental results are the good spreadability of corium–concrete mixtures having large solidification ranges even with viscous silicic melts, the change of microstructure due to cooling rates, the occurrence of a large thermal contact resistance at the corium–substrate interface, the presence of a steep viscosity gradient at the surface, the transient concrete ablation. Furthermore, the experiments showed the presence of the gaseous inclusions in the melt even without concrete substrate. This gas release is linked to the local oxygen content in the melt which is function of the nature of the atmosphere, of the phases (FeOx, UOy, …) and of the substrate. These tests with prototypic material have contributed to the validation of spreading models and codes which are used for the assessment of corium mastering concepts.
Facility is in operation.

Organization
CEA
Type of Facility
Corium
Experiments available
0
Description:

VITI (‘‘VIscosity Temperature Installation’’) experimental assembly: (1) VITI chamber, (2) graphite crucible, (3) ZrCcoating, (4) studied mixture, (5) graphite susceptor, (6) thermal shield, (7) support for crucible, (8) support for thermal shield, (9) inductance coil, (10) pyrometer – measure of Tcrucible, (11) pyrometer – measure of Tmixture, (12) data acquisition

The experiments were dedicated to the selected coating interaction with water reactor corium and with sodium fast reactor corium compositions.
VITI facility has been developed to measure viscosity, density and surface tension on corium up to 2600 C by aerodynamic levitation. But it is also used as small crucibles heating for material interactions tests. Samples of less than 100 g can be studied in VITI.

Organization
CEA
Type of Facility
Corium
Experiments available
1
Description:

Determination of the vaporization rate according to the composition and the thermodynamic conditions of the corium (with FP simulants) was the aim of the COLIMA (COrium LIquid and MAterials) experiments. The facility provided representative conditions of the aerosols suspended inside the containment of PWRs under a severe accident. According to the scientific objectives of each experiment, different configurations of the facility can be used: corium/materials interaction (concrete, ceramics), release of aerosols from the corium (simulating physical-chemistry of oxidic and metallic fission products, without radioactive isotopes except uranium).

COLIMA consists of 1.5m3 tank, where the maximum internal pressure can reach 0.3MPa. The corium can be melted in a crucible by a thermite reaction or an induction coil that can maintain it hot in order to provide a steady state situation up to 3000◦C. The crucible, designed to contain few kilograms of corium, is surrounded by a thermal shield ring and can be placed at the bottom or at the middle of the tank. The walls of the vessel tank are thermally controlled at 150◦C. Portholes, dedicated to the instrumentation, are located at its top, half height and bottom.

Organization
CEA
Type of Facility
Corium
Experiments available
0
Description:

The test section of the KROTOS facility consists of a stainless steel test section bolted to lugs welded on the inner side walls of a stainless steel pressure vessel. The cylindrical pressure vessel, inner diameter 0.4 m, height, 2.21 m, has a thick flat bottom and a flanged flat upper head and is designed to withstand a static pressure of 2.5 MPa at 493 K. The cylindrical test section, inner diameter 200 mm, outer diameter 240 mm, closed at the bottom by either a flat plate or with a gas trigger device, can contain water up to a height of about 1.27 m (about 40 litres).



The KROTOS main objective is to provide basic experimental information on FCI phenomena relevant to severe accident situations in nuclear reactors.

Facility is in operation at CEA. KROTOS was transferred to CEA Cadarache at the end of the JRC-Ispra MFCI programme in 1999.

For the JRC-Ispra KROTOS performed experiments see https://stresa.jrc.ec.europa.eu/facilities/krotos.

Organization
KIT
Type of Facility
Corium
Experiments available
0
Description:

The LIVE facility at the Forschungszentrum Karlsruhe is designed to study the late phase of core degradation, onset of melting and the formation and stability of melt pools in the RPV. Additionally, the regaining of cooling and melt stabilisation in the RPV by flooding the outer RPV or by internal water supply have been investigated.
The experimental programme consists of three different phases. In the first phase (LIVE1) the investigations concentrate on the behavior of a molten pool, which is poured into the lower head of the RPV taking into account possible 3-d effects. The objective was to determine the time dependent local heat flux distribution to the lower head, and the development of crusts, depending on internal melt heating and external cooling modes. The gap formation between the RPV wall and the melt crust as well as the role of phase segregation of a non-eutectic, binary melt on the solidification behavior has been investigated. In the second phase (LIVE2) the experiments were extended to allow multiple melt pours and the presence of water in the lower head. The third phase (LIVE3) dealt with processes during in-core melt pool formation, the stability of the melt pools in the core region during different cooling modes and relocation processes after crust failure.
The experiments have been carried out with different simulant materials. The first melt was a binary mixture of NaNO3 and KNO3 with temperatures up to about 350 °C. In an advanced stage, the second melt was a binary mixture of V2O5 with CuO, MgO or ZnO with temperatures up to 900 °C.
Experiments in the LIVE facility were part of the LACOMERA Project of the EU 5th Framework Programme. Produced experimental database has been used to validate and improve computer models, which had being developed in the area of molten pool formation and cooling in the lower head.
Facility is in operation.

Organization
KIT
Type of Facility
Corium
Experiments available
0
Description:

An important accident management measure for controlling severe accident transients in light water reactors (LWRs) is the injection of water to cool the degrading core. Flooding of the overheated core, which causes quenching of the fuel rods, is considered a worst-case scenario regarding hydrogen generation rates which should not exceed safety-relevant critical values. Before the water succeeds in cooling the uncovered core, there can be an enhanced oxidation of the Zircaloy cladding that in turn causes a sharp increase in temperature, hydrogen production, and fission product release. The complex physico-chemical processes during quenching and their mutual influence is not yet sufficiently known. In most of the code systems describing severe fuel damage the quench phenomena are only modeled in a simplified empirical manner.

Facility is in operation.

Organization
KIT
Type of Facility
Corium
Experiments available
0
Description:

The main components of the facility are scaled about 1:18 linearly to a large European reactor: the containment pressure vessel (volume 14 m³), the RPV-RCS pressure vessel (0.08 m³), the cavity, the subcompartment, and the steam accumulator (0.08 m³). The subcompartment is an annular space around the cavity with a volume of 1.74 m³. The flow path from the cavity into the subcompartment is along the eight stubs modeling the main cooling lines (total flow cross section is 0.0308 m²). The connection from the subcompartment to the containment is by four openings with a diameter of 130 mm in its top plate. The RCS-RPV pressure vessel models the volumes of both the reactor cooling system (RCS) and the reactor pressure vessel (RPV). The RPV model, that serves as crucible for the generation of the melt, is bolted to a plate carrying the RCS-RPV pressure vessel. The hole at the bottom of the melt generator is formed by a graphite annulus. It is closed with a brass plate. The reactor pit is made of concrete and is installed inside a strong steel cylinder. Besides the flow path along the main cooling lines there is the option of a flow out of the cavity straight up into the containment through eight openings with a total cross section of 0.052 m². Depending on the reactor design, that is to be investigated, this cross section is variable.



In case of the modeling of a prototypical scenario, the containment vessel is heated by filling with steam additional to the atmospheric air until the pressure reaches 0.2 MPa. The average gas temperature and the wall temperature inside the vessel is 373 K (100°C) at the end of the heat-up. A metered amount of hydrogen gas (3 mol-%) is added to the vessel at the end of heat-up while fans are running inside the vessel. A gas sample is taken just before the start of the experiment.



The pressure vessel modeling the RPV and RCS volume is electrically heated to the saturation temperature of the planned burst pressure, e.g. to 453 K (180°C at 1.0 MPa). It contains nitrogen at that temperature at 0.1 MPa. The steam accumulator is heated electrically to the saturation temperature of twice the planned burst pressure, e.g. 486 K (213°C at 2.0 MPa). The accumulator is filled with a measured amount of water by a high pressure metering pump to reach that pressure. The RCS pressure vessel and the accumulator are connected by a 25 mm diameter pipe with an electro-pneumatically actuated valve.


The model of the RPV is filled with aluminum-ironoxide thermite. The experiment is started by igniting the thermite electro-chemically at the upper surface of the compacted thermite powder. When a pressure increase in the RPV-RCS pressure vessel verifies that the thermite reaction has started, the valve in the line connected to the accumulator is opened and steam enters the pressure vessel. When the pressure has reached a preset value the valve is automatically closed again. About 5 to 8 seconds after ignition the brass plug at the bottom of the RPV vessel is melted by the 2400 K hot iron-alumina mixture. That initiates the melt ejection. The melt is driven out of the breach by the steam and is dispersed into the cavity and the containment.

Organization
KIT
Type of Facility
Corium
Experiments available
0
Description:

The KAJET erosion test facility is shown in Fig. 10-1. Total melt masses of up to 300 kg can be provided by various types of melt generators. Driving pressures of up to 2.5 MPa can be established. Melt release occurs downward into a vessel which is 1100 mm in diameter and 1900 mm in height and has at its bottom layers of gravel and sand. The pressure inside the vessel can be raised up to 0.3 MPa. The examined samples consisted of siliceous concrete and borosilicate glass concrete. The schematic (Fig. 10-2) helps to explain how the test was conducted. The time scale begins with the start of ejection. The first melt component to be ejected on sample no 1 was iron. Shortly before the end of iron release, the plate carrier was turned by 90° within one second. During that time, the melt changed to oxide as the component to be ejected on sample no 2.

Organization
KIT
Type of Facility
Corium
Experiments available
0
Description:

The test facility consists of a slender cylinder with an effective inner diameter of 0.66 m bearing plane glass windows in the front and back sides. The upper part is occupied by the melt generator which leaves a 0.14 m wide annular space for the steam flow. The facility is entirely closed except for four large venting pipes (4 m long, each with a cross section of 90 cm2) which were also closed in two tests. The space below the melt generator is about 2.2 m high but for the processes to be studied, the actual height of the test water pool was determined by a concave debris catcher that could be mounted at different heights. The test rig was placed inside a large (220 m3) pressure vessel providing a safety barrier and the possibility to perform tests at elevated ambient pressure.

Organization
KIT
Type of Facility
Corium
Experiments available
0
Description:

The QUEOS facility consists of the test vessel, the furnace and the valve system separating the two. The spheres are heated in an electric radiation furnace in an argon atmosphere. The spheres are discharged into the water with a drop height of 130 cm. The diameter of the sphere stream is 100 mm or 180 mm after the discharge from the middle valve and the spheres fall freely without touching any walls.

Facility is in operation.